PLANKMATH

Wall Framing

Wall length and height in, lumber list out — studs with the corners and openings counted, plates in stock lengths, header pieces and nails.

A material count for a simple, non-engineered wall. It is not a structural design, and it does not size headers.

The wall
Openings
On the counter

Your buy list

0

2 × 4 studs · 92-5/8 in precut
Stud count
—
Plates
—
Header pieces
—
Header boards
—
Sheathing
—
Nails
—
Estimated cost
—

A material count, not a structural design. Header depth is not calculated.


Counting a stud wall

A wall is counted the way it is laid out on the plate. Divide the length by the spacing, round up, and add one for the stud that closes the far end: a 12 foot wall at 16 inches on centre is 9 spaces and 10 studs. Then come the studs that are not on layout. Every door or window gets a full-height king stud each side and a shorter jack stud inside it to carry the header, four in all. Every corner gets three extra and every wall that tees in gets two, so there is something to nail the next wall and the drywall to.

The form opens on that 12 foot wall with one door: 10 on layout, 4 at the opening, 14 in all, and 16 to buy with 10 % waste. The studs that would have stood where the door is are not taken back off. They become the cripples over the header, and for a window the ones under the sill, which is why the calculator calls them an allowance and does not count cripples one by one.

Plates and stud length

Three rows of plate run the length of the wall: one on the floor and two on top, the second lapping the joints of the first and tying into the walls it meets. The 12 foot wall takes 36 linear feet, three 12 footers. Studs for an 8 foot wall are sold precut at 92-5/8 inches, so that three plates bring it to 97-1/8 inches and a full sheet of drywall fits under the ceiling board. Enter 9 or 10 feet and the tag switches to the 104-5/8 or 116-5/8 inch precut; enter anything else and it gives the cut length and the stock to cut it from.

Headers: counted, not sized

Give each opening its rough opening width, which for a door is usually 2 inches more than the door itself, and the tag lists the header as two plies 3 inches longer than that, so each end bears on a jack stud. That is a cutting list. It is not a header size. How deep those plies need to be, 2 × 6 or 2 × 12, is a question of span and load answered by the span tables in your building code or by an engineer, and in a wall that holds up a floor or a roof it is the question that matters most.

What this is not

This is a material count for a non-engineered partition or a simple wall. It does not check whether a wall is load-bearing, design shear walls, tall walls or anything in a high-wind or seismic zone, and it does not replace a permit drawing. Once the wall is up, the insulation calculator fills the cavities and the drywall calculator covers them.


On the counter

The assumptions and limits this calculator uses. The form exposes the settings you can change; fixed allowances are described below.

Studs on layout
Wall length ÷ spacing, rounded up, plus one. Not reduced for openings: the studs an opening displaces are the allowance for its cripples
Corners and intersections
3 extra studs per corner, 2 per wall that tees into this one
Openings
2 king studs and 2 jack studs each, bought as full studs. Each window adds one stud for its rough sill, two if the window is wider than the stud is long
Plates
One bottom and a double top, the full wall length. The bottom plate under a door is not deducted; it is cut out after the wall stands. No waste added
Headers
Two plies per opening, each the rough opening plus 3 in, cut from the shortest 8–16 ft board that yields them. A count only: depth is not calculated
Stud length
Precut 92-5/8, 104-5/8 and 116-5/8 in for 8, 9 and 10 ft walls; otherwise height less 4.5 in of plates, from 8–16 ft stock
Waste
10 % by default, on studs only, for the bowed and the split
Sheathing
4 × 8 ft sheets, one face, on the gross wall. Openings are not deducted; their cut-outs are the waste allowance
Nails
An assumed 8 framing nails per stud bought, which covers plate and header nailing, at roughly 47 16d common nails to the pound. Sheathing adds an assumed 0.5 lb of 8d nails per sheet. Both are typical figures, not a nailing schedule
Estimated cost
Before tax, and only the lines you priced
Not included
Blocking, fire stopping, anchors or fasteners into the floor, hold-downs, hangers and housewrap

Questions from the aisle

How many studs do I need for a 12 foot wall?

At 16 inches on centre a 12 foot wall has 9 spaces, so 10 studs on layout. A door opening adds two king studs and two jack studs, which makes 14, and 10% waste rounds that up to 16 studs to buy. With no door it is 11. At 24 inches on centre the same wall with the door is 7 on layout, 11 with the opening and 13 with waste.

Is one stud per foot of wall close enough?

It is a fair guess for a plain wall and it runs short as soon as there are corners and openings. A 20 foot wall at 16 inches with two corners, a door and a window counts 16 studs on layout, 6 at the corners, 8 kings and jacks and 1 for the window sill: 31, or 35 with 10% waste. One per foot would have bought 20.

What length studs do I buy for an 8 foot ceiling?

Precut studs, 92-5/8 inches long. With a bottom plate and a double top plate, three thicknesses of 1.5 inches, the wall stands 97-1/8 inches, which leaves room for ceiling drywall and a gap at the floor under a full 8 foot sheet. The 9 foot precut is 104-5/8 inches and the 10 foot is 116-5/8. Any other height is the wall height less 4.5 inches, cut from the next stock length up.

How much lumber for the top and bottom plates?

Three times the wall length: one bottom plate and a double top plate. A 12 foot wall is 36 linear feet, which is three 12 footers or five 8 footers. The count is done board by board, not by linear feet, because a 9 foot wall needs three 16 footers even though 27 feet would fit on two.

What size header do I need over a door or window?

This calculator does not size headers, and nothing here should be read as doing so. Header depth depends on the span, what the wall carries and your building code’s span tables. What it does count is the pieces: two plies per opening, each 3 inches longer than the rough opening so it sits on the jack studs. A 38 inch door opening takes two pieces 41 inches long, both from one 8 foot board.



Next off the wall

The rest of inside the house — most jobs need two or three of these before the first trip to the store.

All interior calculators Every calculator on the board

The reasoning behind this one

Counting the lumber in a framed wall

Where the assumptions above come from, what changes them, and the mistakes that cost a second trip. Free to read, no account needed.