Insulation
Attic, wall or floor in, bags out — batts or blown-in, with the R-value your climate zone calls for on the tag.
Your buy list
0
bags of R-38 batts- Area to cover
- —
- Coverage per bag
- —
- Batt width
- —
- Recommended here
- —
- Estimated cost
- —
Typical bag coverage — check it against the bag you buy.
Bags, not square feet
Insulation is sold by the bag, and the bag is where the arithmetic hides. A bag of R-13 batts and a bag of R-38 batts are about the same size on the shelf, but the R-38 is three times as thick, so it holds far fewer square feet. The count is area, plus waste, divided by what one bag covers at the R-value you picked, rounded up. The form opens on a 25 × 40 foot attic: 1,000 square feet, 1,050 with 5 % waste, and 25 bags of R-38 batts at an assumed 43 square feet a bag.
Those per-bag figures are assumed typical ones, listed in full under “On the counter” below. Makers pack different piece counts and lengths, so the number on the wrapper in front of you beats any default: type it into the coverage field and the tag follows it.
Blown-in goes by the chart
Loose fill has no fixed coverage. One bag spread thin gives a lot of R-13 or a little R-60, and every bag carries a chart of square feet per bag at each R-value. The bag’s coverage chart governs. The defaults here are one published fibreglass chart and one published cellulose chart: switch the form to blown-in and the same 1,000 square feet at R-38 is 20 bags of fibreglass, settled to about 13.6 inches. Depth is the check on the job. Staple rulers to the trusses before you start and blow to the installed depth the bag lists, which is deeper than the settled one.
What R-value the zone calls for
These are ENERGY STAR’s recommended levels for existing wood-framed homes, by the climate zones of the International Energy Conservation Code, whose 2021 edition they follow. They are guidance for a retrofit. The code your town adopted is what applies to permitted work.
| Climate zone | Attic, uninsulated | Attic, 3–4 in existing | Floor |
|---|---|---|---|
| 1 | R-30 | R-25 | R-13 |
| 2 | R-49 | R-38 | R-13 |
| 3 | R-49 | R-38 | R-19 |
| 4A and 4B | R-60 | R-49 | R-19 |
| 4C, 5 and 6 | R-60 | R-49 | R-30 |
| 7 and 8 | R-60 | R-49 | R-38 |
Walls are different, because the stud decides. A 2 × 4 cavity is 3.5 inches deep and takes an R-13 or R-15 batt; a 2 × 6 cavity is 5.5 inches and takes R-19 or R-21. A thicker batt squeezed into a shallower cavity loses R-value, so the tag warns when the target does not fit. The same guidance adds insulating sheathing outside the studs in colder zones, but only when the siding is coming off anyway.
Framing in or out
The calculator leaves the framing in the area by default and says so. Studs at 16 inches take up 9.4 % of a wall, and that surplus is what covers the batts cut to fit a narrow bay and the ones split around wiring. Tick “Deduct the framing” for a tighter count on a long clean run. If the wall is not built yet, the wall framing calculator counts the studs, and the drywall calculator covers what goes over the batts.
On the counter
The assumptions and limits this calculator uses. The form exposes the settings you can change; fixed allowances are described below.
- Batt bags
- Assumed typical bag contents for 15 in batts (16 in framing): R-13 106 sq ft, R-15 68, R-19 78, R-21 68, R-30 59, R-38 43, R-49 32. For 23 in batts (24 in framing): 163, 104, 119, 104, 88, 64, 48. Bags vary by maker and length; type the figure off yours
- R-60 in batts
- Counted as two layers of R-30, the second laid across the first
- Loose-fill fibreglass
- Coverage per bag from the Owens Corning AttiCat chart: R-13 169.8 sq ft, R-19 110.7, R-30 68.5, R-38 52.6, R-49 39.9, R-60 31.8. R-15 (150) and R-21 (100) are interpolated. Depth at an assumed R-2.8 per inch settled
- Cellulose
- From the Greenfiber SANCTUARY chart for a 25 lb bag: R-13 65.8 sq ft, R-19 44.2, R-30 25.9, R-38 19, R-49 14.1, R-60 11.6; R-15 and R-21 are interpolated. Depth at R-3.65 per inch settled, from the same chart. Brands differ more than fibreglass does; the bag’s coverage chart governs
- Framing
- Left in the area unless you tick the box. Ticked, batts lose 1.5 in of framing in every spacing: 9.4 % at 16 in, 6.25 % at 24 in. Plates, headers and doubled studs are not counted. Never deducted for blown-in
- Waste
- 5 % by default, on batts and blown-in alike
- Recommended R-values
- ENERGY STAR’s recommended home insulation R-values for existing wood-framed homes, which follow the 2021 International Energy Conservation Code. Guidance only; local code governs
- Estimated cost
- Before tax, and only the lines you priced
- Not included
- Blower rental, vent baffles, air sealing, vapour retarder, and dense-packed walls, which are sold on a different coverage chart
Questions from the aisle
How many bags of blown-in insulation do I need for 1,000 square feet?
It depends on the R-value and the product. With loose-fill fibreglass at the coverage this calculator assumes, 1,000 square feet of attic takes 15 bags for R-30, 20 for R-38, 26 for R-49 and 32 for R-60, before any waste allowance. Cellulose comes in smaller bags that each cover less: about 53 bags for R-38 at an assumed 19 square feet a bag. The coverage chart printed on the bag you buy governs, and the form has a field for it.
How many bags of batt insulation for a 1,000 square foot attic?
At R-30 with joists 16 inches on centre, a typical bag holds about 59 square feet, so 1,000 square feet plus 5% waste is 18 bags. R-38 batts are thicker and pack fewer to the bag, about 43 square feet, which makes it 25 bags. R-60 is usually two layers of R-30 laid crosswise, which doubles the R-30 count to 36.
What R-value do I need?
ENERGY STAR publishes recommended levels by climate zone, based on the 2021 International Energy Conservation Code. For an uninsulated attic it is R-30 in zone 1, R-49 in zones 2 and 3, and R-60 from zone 4 north. For floors it runs from R-13 in zones 1 and 2 to R-38 in zones 7 and 8. Pick your zone on the form and the tag shows the line that applies. Your local building code is what an inspector enforces, and it can differ.
How thick is R-38 or R-49 blown-in insulation?
At the R-2.8 per inch this calculator assumes for loose-fill fibreglass, R-38 settles to about 13.6 inches and R-49 to 17.5. Cellulose at R-3.65 per inch is 10.4 inches for R-38 and 13.4 for R-49. Blow it deeper than that: the R-value is rated at settled thickness, and the bag lists the installed depth that settles to it.
Should I subtract the studs and joists?
Not by default, and the calculator says so. A batt bag’s square footage is the area of the batts in it, and studs take up 1.5 inches of every 16, which is 9.4% of the wall (6.25% at 24 inches). Leaving that in covers the offcuts and the odd narrow bay. Tick the box if you want it out: 1,000 square feet of R-30 at 16 inches drops from 18 bags to 17. Blown-in over an attic floor buries the joists, so nothing is deducted there either way.
The reasoning behind this one
Insulation: from an R-value to a bag count
Where the assumptions above come from, what changes them, and the mistakes that cost a second trip. Free to read, no account needed.